How to Cut PIR Insulation Board (Celotex, Kingspan): Tools and Tips
PIR insulation only performs as well as it is fitted. A board cut 10mm short leaves a gap that lets cold air bypass the insulation, and a ragged edge makes a tight fit impossible. The good news is that clean cuts need no special kit, just the right technique. This guide covers the tools, the manufacturers' recommended cutting methods and the tricks that make fitting between rafters, joists and studs quicker. It applies to foil-faced PIR boards generally, including Celotex (now sold as Sopratherm), Kingspan and Recticel; always check the datasheet for the board you are using.
Tools you need
- Tape measure, pencil or marker, and a long straight edge (a spirit level or a straight length of timber or metal works)
- A long, sharp knife or insulation knife, with spare blades
- A fine-toothed handsaw or insulation saw for thicker boards (optional: a plunge saw on a guide rail for lots of long, straight cuts)
- A combination square, and a sliding bevel for angled cuts
- Gloves, a dust mask and eye protection
Two ways to cut PIR board
Kingspan's guidance for Thermapitch TP10, which applies to foil-faced PIR boards generally, is to cut either with a fine-toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Recticel's BBA certificate for Eurothane GP says the same: a sharp knife or a fine-toothed saw.
Score and snap (thinner boards)
- Mark the cut on the face and lay the straight edge along the line.
- Score firmly through the foil facing and well into the foam, keeping the blade upright.
- Move the board so the scored line sits over the edge of a bench or a length of timber, then press down to snap it cleanly.
- Cut through the facing on the other side with the knife.
Sawing (thicker boards)
- Mark the line on both faces and down the edge, using a square, so you can check the saw stays upright.
- Support the board on both sides of the cut so it does not sag and pinch the blade.
- Saw with long, steady strokes, keeping the blade square to the board. A long-bladed insulation saw makes this easier on boards of 100mm and more.
Which tool for which board?
| Tool | Best for | Things to know |
|---|---|---|
| Sharp knife (long snap-off or insulation knife) | Thin boards, roughly up to 25–30mm, by score and snap; trimming facings | Change or snap the blade often. A blunt blade tears the foil and crumbles the foam. |
| Fine-toothed handsaw | Most boards, and angled cuts | Quiet, little dust, no power needed. Keep the saw upright and let the teeth do the work. |
| Insulation saw | Thick boards (100mm and more) and bulk cutting | A long blade cuts right through deep boards in one pass, which keeps edges square. |
| Plunge saw on a guide rail (track saw) | Lots of long, dead-straight rip cuts, for example strips for rafters at a set width | Fast and accurate, but makes much more fine dust. Only use with dust extraction and a mask, and check the depth of cut reaches through the board. |
Choosing a blade
- Handsaws: a fine tooth gives a cleaner edge and less tearing of the foil than a coarse general-purpose saw. Keep a saw just for insulation, as dust and foil dull the teeth.
- Power saws: use a sharp, fine-toothed blade suited to the saw, and set the depth just deeper than the board. A blunt or coarse blade rips the facing and throws far more dust.
- Knives: use a long blade so you can score deeply in one or two passes, and snap off or change blades as soon as they start to drag.
Dust control and PPE
Hand tools make far less dust than power tools, so use a knife or handsaw wherever you can, especially in a loft or other confined space.
- Mask: wear a well-fitting disposable dust mask (FFP2 or, for more protection, FFP3), particularly when power cutting or working in a loft.
- Eyes and hands: safety glasses and gloves. Foil edges can be sharp.
- Extraction: if you use a power saw, connect a suitable dust extractor, and cut outside or in a well-ventilated area where you can.
- Clean up: vacuum dust rather than sweeping it, which puts it back into the air.
Getting a tight fit between rafters, joists and studs
- Measure every gap. Kingspan advises measuring the distance between rafters, joists or studs before cutting, as spacings vary. Measure at both ends of each bay, as old timbers are rarely parallel.
- Cut to fit snugly. Boards should be lightly butted, with a tight fit against the timbers. Do not force oversized boards in, as they can bow and leave gaps behind.
- Plan your strips. A 1200mm-wide sheet gives two strips for rafters at 600mm centres, or three for joists at 400mm centres, with a narrow offcut. Cutting across the sheet rather than along it can give less waste in short bays.
- Use a sliding bevel for angles. Copy the angle of the rafter at the eaves or ridge, transfer it to the board and cut through with the saw.
- Cut neatly around services. Cut notches for pipes and cables slightly oversize and fill the gap, rather than tearing the foam.
Filling gaps and taping joints
Even careful cutting leaves small gaps. Kingspan recommends filling them with expanding urethane sealant, and Recticel's BBA certificate allows strips cut from the board or expanding PU foam. Where boards form part of the airtight or vapour control layer, tape the joints with foil tape such as Alpha foil tape 75mm. Keep the foil faces clean and dry so the tape sticks.
Staying safe
- Cutting PIR creates fine dust, so wear gloves, a dust mask and eye protection, especially in a confined loft.
- Kingspan notes that the reflective facings reflect light and UV. In bright sunshine, wear UV-protective glasses and protect exposed skin.
- Foil facings are slippery when wet. Pick up offcuts as you go rather than leaving them where people walk.
Safety checklist
- Read the datasheet and health and safety information for the board you are using.
- Gloves, eye protection and a dust mask on before you start cutting.
- Board supported on both sides of the cut, on a stable surface or trestles.
- Sharp blades only, and cut away from your body and hands.
- Power saws: extraction connected, guards working, depth set, cable out of the way.
- In lofts: boards across the joists to kneel on, and good lighting.
- Offcuts and dust cleared as you go, especially from walkways and ladders.
- Bright sunshine: UV-protective glasses and covered skin when handling foil-faced boards (Kingspan guidance).
Frequently asked questions
Can I cut Celotex with a knife?
Thinner Celotex boards (now Sopratherm), like other foil-faced PIR boards, can be scored and snapped with a sharp knife. For thicker boards a fine-toothed handsaw or insulation saw gives a straighter, squarer edge. Check the Sopratherm datasheet linked on each Celotex board page for the manufacturer's guidance.
Can I cut PIR with a jigsaw?
You can, but the manufacturers recommend a sharp knife or fine-toothed handsaw. A jigsaw blade is usually too short for thick boards and makes a lot of dust.
What thickness do I need?
That depends on the element and the U-value you need to reach. Our guide to what thickness of PIR insulation you need and our PIR U-value calculator will help. For more fitting tips, see 5 common insulation installation mistakes.
Order your PIR boards
We stock Celotex boards (now Sopratherm) such as GA4000 100mm, Kingspan Thermapitch TP10, Recticel Eurothane GP and more, in a wide range of thicknesses. Browse all PIR insulation boards or our wall insulation boards, and tape the joints with Alpha foil tape. Not sure how many boards to order? Use our insulation calculator, check the thickness with the PIR U-value calculator, or see all our calculators. Free delivery on general orders over £400 ex VAT. Celotex: £400 ex VAT minimum, with free delivery in England. Prices are shown ex VAT, and we deliver across England, mainland Wales and mainland Scotland (see delivery information). Call us on 03330 908479, email sales@insulationwarehousedirect.co.uk, or order online.
Sources: Kingspan Thermapitch TP10 brochure (sitework: cutting, fitting and health and safety); Recticel Eurothane GP BBA certificate 24/7254, sections A.2 and A.26. Correct at the time of writing.