How to Fit Insulated Plasterboard to a Solid Wall
Insulated plasterboard is the usual way to insulate a solid brick, stone or block wall from the inside. Insulation comes already bonded to tapered-edge plasterboard, so you line and insulate in one go. This guide is for fixing those boards straight to masonry with adhesive dabs and secondary mechanical fixings (dot-and-dab). For battens, studs, metal linings and ceilings, use our separate guide on how to install insulated plasterboard on battens, studs and ceilings.
Shop this. Kingspan K118 and Celotex PL4000, at trade prices, for bonding to a solid wall.
Quick answer
Prepare a dry, sound wall, bed the boards on Gyproc DriWall Adhesive with a continuous ribbon around the edges, then add the mechanical fixings the board maker specifies, such as nailable plugs. Tape or skim the joints. In England, renovating an existing wall with internal insulation typically aims for 0.30 W/m²K under Approved Document L Table 4.3 — Building Control or the designer must confirm the figure and the thickness for your wall.
Tools
- Tape measure, pencil, spirit level and a long straight edge.
- Plasterer’s hawk and trowel, or a bonding trowel, for the adhesive.
- Pad saw or knife for the boards, and a hammer drill with a masonry bit for the mechanical fixings.
- Mixing bucket, paddle mixer, and PPE: gloves, eye protection and a dust mask.
Materials
- Insulated plasterboard from our insulated plasterboard range: Kingspan Kooltherm K118 (phenolic, sold in full packs) or Celotex / Sopratherm PL4000 (PIR, sold per sheet).
- Gyproc DriWall Adhesive 25kg for the dabs and the perimeter ribbon.
- Secondary mechanical fixings into the masonry, such as British Gypsum nailable plugs, in the length the board maker specifies for your board thickness.
- Thistle ProTape FT50 and Gyproc Joint Filler if you are taping and jointing, plus foil tape if the board maker asks you to seal foil joints as the vapour layer.
Use the plasterboard calculator to estimate how many sheets you need, and see how to cut plasterboard for cutting tips, including foam-backed boards.
Which board: K118 or PL4000?
- Kingspan Kooltherm K118 has a phenolic core (declared λ 0.019 W/mK) bonded to 12.5mm tapered-edge plasterboard, 2400 × 1200mm. Kingspan states that it has an integral vapour control layer. We sell it in full packs only.
- Celotex PL4000 (now Sopratherm PL4000) has a PIR core (declared λ 0.022 W/mK) bonded to 12.5mm tapered-edge plasterboard, 2400 × 1200mm. Celotex says it can be fixed to masonry with dabs and mechanical fixings, or to timber or metal studs. We sell it per sheet, from 37.5mm to 77.5mm.
The product name is the overall thickness, so a 62.5mm board is 50mm of insulation plus 12.5mm of plasterboard. Our K118 vs PL4000 comparison covers the differences in more detail.
What thickness do you need?
In England, Approved Document L Table 4.3 typically asks for 0.30 W/m²K when you insulate an existing wall internally as a renovation. A lesser standard may be acceptable if meeting it would cut the floor area of the room by more than 5%. Wales, Scotland and new-build walls can differ. See what U-value you need under Part L in England and what thickness of insulation for walls. Building Control or the designer must confirm the target and the thickness for your wall.
These R-values are the manufacturers' figures as shown on our product pages and in our comparison guide. Kingspan quotes K118 for the insulant only. The U-value of the finished wall also depends on the existing masonry, plaster, fixings and any residual cavities, so use these as a starting point only.
| Overall thickness | Kingspan K118 R-value (m²K/W) | Celotex PL4000 R-value (m²K/W) |
|---|---|---|
| 37.5mm | 1.30 | 1.20 |
| 42.5mm | 1.55 | – |
| 52.5mm | 2.10 | 1.85 |
| 57.5mm | 2.35 | – |
| 62.5mm | 2.60 | 2.30 |
| 72.5mm | 3.15 | – |
| 77.5mm | – | 3.00 |
| 82.5mm | 3.65 | – |
You can get a first estimate with our PIR U-value calculator. Thinner boards still improve a solid wall where space is tight, but they may need Building Control's agreement if they do not meet the target on their own.
Before you start
- Check for damp and condensation risk. Internal wall insulation changes how heat and moisture move through the wall. Fix penetrating or rising damp first, and ask the designer for a condensation risk analysis before you start.
- Prepare the wall. Take off skirtings, picture rails and window boards, and remove finishes with a high vapour resistance such as vinyl wallpaper or gloss paint. The wall should be sound, clean and reasonably flat.
- Plan heavy fittings. Radiators, cupboards and TVs should be fixed back to the masonry, or to timber supports built into the lining.
- Choose the method. Dot-and-dab suits a reasonably even wall. If the wall is very uneven, or you need a void for services, fix to battens or a metal lining instead — that is covered in the mechanical installation guide.
How to fit insulated plasterboard with dot-and-dab
- Mix the adhesive and plan the layout. Mix Gyproc DriWall Adhesive as the bag instructs. Check the wall is plumb, mark openings, and dry-fit the first board so you know where the joints will fall. Cut boards as needed — see how to cut plasterboard.
- Seal the edges. Apply a continuous ribbon of adhesive around the perimeter of the wall and around window and door openings. This limits air movement behind the boards and helps the lining act as part of the air and vapour control.
- Apply the dabs. Put adhesive dabs in vertical rows on the wall (or on the back of the board, if the maker allows that), following the board and adhesive instructions for dab size, spacing and coverage. Do not skimp at the edges.
- Position the boards. Press each board into the adhesive, plasterboard face out, and tap it back to line and level with a straight edge. Butt the edges tightly so there are no gaps in the insulation. Leave a small gap at the floor, typically around 5–10mm, so the board is not sitting in damp or hard against the screed.
- Add mechanical fixings. Once the boards are lined up, secure each sheet to the masonry with the secondary fixings the manufacturer specifies, such as nailable plugs. Use the number, positions and length given in the board data — adhesive alone is not enough. Choose fixings suited to insulated laminates, so they do not crush the foam or create an unnecessary cold bridge.
- Detail openings and services. Line window and door reveals with a thinner insulated board where there is room, to reduce cold spots. Bring sockets and switches forward, and seal around boxes and pipes. Do not leave open gaps in the insulation.
- Seal the joints and finish. If the board maker asks for foil joints to be taped as the vapour layer, use foil tape — see when to use foil tape. Then tape and joint the plasterboard face with fibre tape and jointing compound, or skim. Seal the perimeter with a flexible or acoustic sealant.
Common mistakes
- Dot-and-dab on a damp wall, or using the lining to hide a damp problem.
- Missing the continuous adhesive ribbon at the edges, so air can move behind the boards.
- Leaving out the mechanical fixings.
- Leaving gaps at reveals, sockets or board edges, which become cold spots.
- Assuming a 37.5mm board will always meet 0.30 W/m²K on every solid wall — the existing wall and the fixing method both count, and Building Control must agree the figure.
Frequently asked questions
Can I fix insulated plasterboard to battens instead?
Yes. K118 and PL4000 can both be screwed to timber battens or a metal lining, which often suits an uneven wall or a wall that needs a service void. See how to install insulated plasterboard on battens, studs and ceilings.
Do I need a separate vapour control layer?
It depends on the board and the wall. Kingspan states that K118 has an integral vapour control layer. For PL4000, taped foil joints are often used as the air and vapour control layer. Follow the manufacturer's detailing and the condensation risk analysis for your wall — do not add a second barrier in the wrong place.
Can I screw the boards straight into the brick, with no adhesive?
Not as a standard method. On masonry, the usual routes are dot-and-dab with secondary mechanical fixings, or a batten or metal lining. Follow the board maker's method.
Related guides and products
Browse insulated plasterboard, then read how to install insulated plasterboard on battens, studs and ceilings, K118 vs PL4000, and whether insulated plasterboard is worth it.
Most orders over £400 + VAT are delivered free across England, with delivery to mainland Wales and Scotland too. Mainland Wales and mainland Scotland: Celotex insulation and Knauf loft roll have £40 ex VAT delivery on every order; ceilings have a £400 ex VAT minimum plus £40 ex VAT delivery; British Gypsum plaster and plasterboard have a £400 ex VAT minimum plus £40 ex VAT delivery. We do not deliver to Northern Ireland or the Scottish islands. We are delivery only and do not offer collection. Delivery charges and minimum orders differ by product group; see our delivery information. Outside England? Call us or contact us for a quote. Call us on 03330 908479 (Mon–Thu 8am–5pm, Fri 8am–12pm), email sales@insulationwarehousedirect.co.uk, or order online.
Sources: Kingspan Kooltherm K118 and Celotex / Sopratherm PL4000 product data as shown on our product pages and in our K118 vs PL4000 comparison; Approved Document L, Volume 1 (GOV.UK), Table 4.3, as already cited in our Part L guide. Figures are indicative. Building Control or the designer must confirm the U-value for your wall.